Go to main content
Oracle® Server X5-4 Service Manual

Exit Print View

Updated: December 2015
 
 

Verify Removal of an NVMe Storage Drive

  • Verify that the NVMe drive has been removed. Type:

    # lspci -nnd :0953

    This commands returns output similar to the following:

    # lspci -nnd :0953
    13:00.0 Non-Volatile memory controller [0108]: Intel Corporation Device [8086:0953] (rev 01)
    14:00.0 Non-Volatile memory controller [0108]: Intel Corporation Device [8086:0953] (rev 01)
    15:00.0 Non-Volatile memory controller [0108]: Intel Corporation Device [8086:0953] (rev 01)

    Note that address 12:00.0, which represents PCIe slot 100 and is the drive labeled NVMe0 on the system front panel and the drive powered off in the example shown in Prepare an NVMe Storage Drive for Removal, is not listed.