Prepare the Server for Cold Service (Oracle ILOM Web Interface)

This procedure describes how to prepare the server for cold service to remove, replace, or install cold-serviceable components. A cold-service component must be serviced when the server is completely powered off and AC cords have been removed from the back panel AC power block. For more information about component serviceability, see Component Serviceability Requirements.

This procedure is performed locally and requires physical access to the server front and back panels.

  1. Log in to the System A or System B service processor Oracle ILOM web interface using an Administrator account.

    Direct a web browser to Oracle ILOM using the IP address of the server SP. Log in as a user with root or administrator privileges. See Accessing Oracle ILOM in Oracle Server X7-8 Installation Guide.

    For more information, see Using Oracle ILOM in Oracle Server X7-8 Installation Guide.

    The Oracle ILOM web interface System Information → Summary Information page appears.

  2. In the Actions section of the Summary Information page, verify that the Power State is ON.

    If the Power State status shows off, the server is already powered off.

  3. Power off the server. In the Actions section of the Summary Information page, click the Power State Turn Off button.

    This action powers off the server to Standby power mode. For more power off options, see Powering Down the Server.


    image:A screen capture showing the Actions section of the Summary                                 page.
  4. In the Actions section of the Summary Information page, click the Locator Indicator Turn On button.

    This action activates the Locate Button/LED on the server front panel. For other options, see Managing the Locate Button/LED.

  5. Click OK.
  6. Once at the service location, press the Locate Button/LED to deactivate the indicator.

    For more information, see Control the Locate Button/LED Locally.

  7. Disconnect the four server power cords from the AC power block.

    Caution

    Caution  -  Data loss. Removing the power cords when the server is in Main power mode results in an immediate shut down of the server. Do not remove the power cord if the server is in Main power mode. Power off the server to Standby power mode first.


  8. Set up an ESD-safe space at the service location.

    Set up a space where you can place components. See Electrostatic Discharge and Static Prevention Measures.

  9. Perform cold-service removal and installation procedures on components.

    See Servicing Components.