A
- AC power block
- indicatorsAC Power Block Inlet Indicators
- AC power inlet locationsAC Input Power Block Locations
- add-in cards
- configuration utilities in UEFI BIOSConfiguration Utilities for Add-In Cards
- Advanced BIOS screenBIOS Advanced Menu Selections
- antistatic measures
- matUsing an Antistatic Mat
- removingPrepare the Server for Operation
- wrist strapUsing an Antistatic Wrist Strap
- assign serial port output
- Oracle ILOM web interfaceAssign Serial Port Output (Oracle ILOM Web Interface)
- Oracle ILOM CLIAssign Serial Port Output (Oracle ILOM CLI)
- attaching devices to serverAttaching Devices to the Server
- ATTN buttons
- dual PCIe card carrier (DPCC)DPCC and PCIe Card Slot Locations and Numbering
- Auto Service RequestAuto Service Requests
B
- back panel
- connecting cablesBack Panel Connector Locations
- backplanes, storage driveSMOD Motherboard
- battery
- installingInstall the System Battery
- locationSMOD Components
- removingRemove the System Battery
- serviceabilityField-Replaceable Units
- system, replacingServicing the System Battery (CRU)
- BIOS
- configuring serial port sharingConfiguring Serial Port and Network Port Sharing
- Ethernet ports booting priorityEthernet Device Naming
- factory defaults, verifyingVerify BIOS Factory Default Settings
- BIOS Setup Utility
- accessing
- Access BIOS Setup Utility Menus
- Accessing the BIOS Setup Utility
- Advanced screenBIOS Advanced Menu Selections
- Boot screenBIOS Boot Menu Selections
- configuration managementManage the BIOS Configuration
- exiting fromExit BIOS Setup Utility
- function keysBIOS Key Mappings
- IO screenBIOS IO Menu Selections
- Main screenBIOS Main Menu Selections
- menus, accessingAccess BIOS Setup Utility Menus
- navigating menu optionsNavigate BIOS Setup Utility Menus
- Save and Exit screenBIOS Save and Exit Menu Selections
- setup screens summaryBIOS Setup Utility Menus
- shortcut key sequencesBIOS Key Mappings
- TPM supportConfigure TPM Support
- UEFI BIOSUsing UEFI BIOS
- boot device, selectingSelect a Temporary Boot Device
- buttons
- ATTNDPCC and PCIe Card Slot Locations and Numbering
- CMOD fault remind
- Troubleshooting Using a CMOD Fault Remind Test Circuit
- Switches and Buttons Reference
- fault remindIdentify and Remove a Faulty Processor
- host resetSwitches and Buttons Reference
- back panelBack Panel Pinhole Switches
- Locate Button/LED
- Managing the Locate Button/LED
- Locate Button/LED Indicator On
- Front Indicator Module (FIM) Panel
- Switches and Buttons Reference
- NMISwitches and Buttons Reference
- back panelBack Panel Pinhole Switches
- On/Standby
- Front Indicator Module (FIM) Panel
- Switches and Buttons Reference
- Power
- Power Off the Server for Immediate Shutdown (Power Button)
- Power Off the Server Gracefully (Power Button)
- SP resetSwitches and Buttons Reference
- back panelBack Panel Pinhole Switches
C
- carrier
- dual PCIe card carrier (DPCC)Servicing PCIe Cards and Carriers (CRU)
- processorsCMOD Components
- charge status indicatorTroubleshooting Using a CMOD Fault Remind Test Circuit
- chassis
- featuresChassis Features
- front panel componentsChassis Front Panel Components
- internal componentsChassis Internal Components
- overviewServer Chassis Overview
- clearing faultsClear Hardware Fault Messages (Oracle ILOM)
- CMOD
- shippingPrepare a CMOD for Replacement
- cold service, preparing the server
- Oracle ILOM CLIPrepare the Server for Cold Service (Oracle ILOM CLI)
- Oracle ILOM Web InterfacePrepare the Server for Cold Service (Oracle ILOM Web Interface)
- command-line interface (CLI), Oracle ILOM
- controlling Locate Button/LED indicatorTurn On the Locate Button/LED Remotely (Oracle ILOM CLI)
- complete power removal
- Power Control, Shutdown, and Reset States
- Remove Power
- Powering Down the Server
- component
- back panelBack Panel Components
- back panel accessibleChassis Back Panel Components
- chassis front panel accessibleChassis Front Panel Components
- chassis internal componentsChassis Internal Components
- CPU module (CMOD)CMOD Components
- DIMMsCMOD Memory
- field-replaceable units (FRUs)System Components (FRUs) Network Access Control (NAC) Names
- filler panelsComponent Filler Panels and Non-Powered Components
- front panelFront Panel Components
- identificationReplaceable Components
- indicatorsSystem Indicators Network Access Control (NAC) Names
- locationsIllustrated Parts Breakdown
- monitoringMonitoring System Components
- monitoring faultsMonitoring Component Health and Faults Using Oracle ILOM
- processorsCMOD Processor
- replaceableReplaceable Components
- serviceability requirements
- Field-Replaceable Units
- Customer-Replaceable Units
- Component Serviceability Requirements
- SMOD
- SMOD Components
- System Module (SMOD) Overview
- storage drivesServer Storage Drives
- system sensorsSystem Sensors Network Access Control (NAC) Names
- configuring the server
- dual 4-Socket server to single 8-Socket serverConfigure Dual 4-Socket Server to Single 8-Socket Server (CRU)
- dual 4-socket system (2x4)System Socket Mode Configurations
- descriptionDual 4-Socket (2x4) Servers
- Oracle X7-8 CPU PackagesOracle X7-8 CPU Packages
- single 4-Socket server to single 8-Socket serverConfigure Single 4-Socket Server to Single 8-Socket Server (FRU)
- single 4-socket system (1x4)System Socket Mode Configurations
- descriptionSingle 4-Socket (1x4) Server
- single 8-Socket server to dual 4-Socket server
- Configure Single 8-Socket Server to Dual 4-Socket Server (CRU)
- Configure Single 4-Socket Server to Dual 4-Socket Servers (FRU)
- single 8-socket system (1x8)System Socket Mode Configurations
- descriptionSingle 8-Socket (1x8) Server
- verifying CMOD configurationVerify the CMOD Configuration
- verifying server socket modeVerify the Current Socket Mode Configuration
- connecting
- back panelBack Panel Connector Locations
- devices to serverAttaching Devices to the Server
- external cablesAttach Devices to the Server
- contacting supportContacting Support
- controlsControls and Indicators
- back panel
- About Controls and Indicators
- Back Panel Components
- About Controls and Connectors
- front panel
- About Controls and Indicators
- Front Panel Components
- About Controls and Connectors
- Locate Button/LED indicatorControl the Locate Button/LED Locally
- CLITurn On the Locate Button/LED Remotely (Oracle ILOM CLI)
- cooling
- fan modulesCooling Fan Power
- subsystemCooling Subsystem
- zonesCooling Zones
- CPU module (CMOD)
- componentsCMOD Components
- cover, removing and installing
- Install the CMOD Cover
- Remove the CMOD Cover
- descriptionCPU Module (CMOD) Overview
- fan module power supplyCMOD and Fan Module Power
- fault remind circuitCMOD Components
- installingInstall a CMOD
- memory
- CMOD Memory
- CMOD Components
- memory slot locationsDIMM Physical Layout
- overviewCPU Module (CMOD) Overview
- processors
- CMOD Processor
- CMOD Components
- removingRemove a CMOD
- rulesCMOD Population Rules
- serviceServicing CPU Module (CMOD) Components (FRU)
- slot designationsCMOD Slot Locations and Numbering
- CPU Module Package
- Oracle X7-8 CPU PackagesOracle X7-8 CPU Packages
- customer-replaceable units (CRUs)
- descriptionComponent Serviceability Requirements
- serviceabilityCustomer-Replaceable Units
D
- diagnostics
- serverTroubleshooting and Diagnostics
- toolsDiagnostic Tools
- DIMMs
- fault LEDs
- inconsistencies with BIOSInconsistencies Between DIMM Fault Indicators and the BIOS Isolation of
Faulty DIMMs
- identifying a faulty DIMMIdentify and Remove a Faulty DIMM
- installingInstall a DIMM
- labelsDIMM Rank Classification Labels
- overviewCMOD Memory
- physical layoutDIMM Physical Layout
- population rules
- DIMM Rules
- DIMM Population Rules
- population scenariosDIMM Population Scenarios
- rank classification labelsDIMM Rank Classification Labels
- removingIdentify and Remove a Faulty DIMM
- replacingIdentify and Remove a Faulty DIMM
- serviceServicing DIMMs (CRU)
- serviceabilityField-Replaceable Units
- slot locationCMOD Components
- slot locationsDIMM Physical Layout
- slot numberingDIMM Slot Numbering and Color Coding
- slot population orderDIMM Slot Population Order
- speedsDIMM Operating Speeds
- supported configurationsDIMM Population Rules
- disk drive backplanes
- serviceabilityField-Replaceable Units
- DPCC
- dual PCIe card carrier (DPCC)Dual PCIe Card Carriers (DPCCs)
- serviceabilityCustomer-Replaceable Units
- dual PCIe card carrier (DPCC)
- indicator panelsDPCC Indicator Panel
- indicatorsDual PCIe Card Carrier (DPCC) Indicators
- installing componentsInstall a DPCC
- location
- Dual PCIe Card Carrier (DPCC)
- Chassis Back Panel Components
- overview
- Dual PCIe Card Carriers (DPCCs)
- PCIe Card and DPCC Overview
- population rulesDPCC Population Rules
- removingRemove a DPCC
- serviceServicing PCIe Cards and Carriers (CRU)
- slot locationsDPCC and PCIe Card Slot Locations and Numbering
- slotsServer PCIe Card Slots
E
- electrostatic discharge (ESD) prevention measuresElectrostatic Discharge and Static Prevention Measures
- energy storage module (ESM)
- locationSMOD Components
- replacingReplace the Energy Storage Module
- serviceServicing the Energy Storage Module and Cables (CRU)
- equipment and tools
- required for serviceRequired Tools and Equipment
- ESM extension cable
- locationSMOD Components
- replacingReplace the ESM Extension Cable
- serviceServicing the Energy Storage Module and Cables (CRU)
- Ethernet
- connecting cablesAttach Devices to the Server
- port device namingEthernet Device Naming
- Ethernet ports
- booting priorityEthernet Device Naming
- device and driver namingEthernet Device Naming
- exploded view of serverIllustrated Parts Breakdown
F
- fan frame
- installingInstall a Fan Frame
- removingRemove a Fan Frame
- serviceServicing Fan Modules (CRU) and Fan Frames (CRU)
- serviceabilityCustomer-Replaceable Units
- fan modules
- coolingCooling Subsystem
- designationsFan Module Locations and Numbering
- faultFan Module Fault
- indicatorsFan Module (FM) Indicators
- installingInstall a Fan Module
- Main powerPrepare the Server for Warm Service (Oracle ILOM CLI)
- powerCooling Fan Power
- redundancyFan Module Redundancy
- removingRemove a Fan Module
- serviceServicing Fan Modules (CRU) and Fan Frames (CRU)
- serviceabilityCustomer-Replaceable Units
- warningWarning Label
- fault
- fan modulesFan Module Fault
- memoryMemory Fault
- over-temperatureOver Temperature Condition
- power supply (PS)PS Fault
- processorsCPU Fault
- service processor (SP)Service Processor Fault
- fault management shell
- Oracle ILOM
- Clear Hardware Fault Messages (Oracle ILOM)
- Managing Server Hardware Faults Using the Oracle ILOM Fault Management
Shell
- fault remind button
- identifying failed processorsIdentify and Remove a Faulty Processor
- locationIdentify and Remove a Faulty Processor
- fault remind circuitCMOD Components
- faults
- clearingClear Hardware Fault Messages (Oracle ILOM)
- fmadm toolClear Hardware Fault Messages (Oracle ILOM)
- serverDetecting and Managing Server Faults
- features
- chassisChassis Features
- componentProduct Description
- field-replaceable units (FRUs)
- componentsSystem Components (FRUs) Network Access Control (NAC) Names
- descriptionComponent Serviceability Requirements
- NAC namesSystem Components (FRUs) Network Access Control (NAC) Names
- serviceabilityField-Replaceable Units
- front indicator module (FIM)
- installingInstall the FIM
- locationFront Indicator Module (FIM) Panel
- removingRemove the FIM
- serviceServicing the Front Indicator Module (FRU)
- serviceabilityField-Replaceable Units
- function keys within BIOS Setup UtilityBIOS Key Mappings
G
- graceful power off
- Power Control, Shutdown, and Reset States
- Powering Down the Server
H
- heatsink and processor
- locationCMOD Components
- help, gettingGetting Help
- host
- reset buttonSwitches and Buttons Reference
- host bus adapter (HBA)
- installingInstall the HBA Card
- locationSMOD Components
- removingRemove the HBA Card
- serviceServicing the Host Bus Adapter (HBA) Card (FRU)
- host reset buttonBack Panel Pinhole Switches
- hot service, preparing the server
- Oracle ILOM CLIPrepare the Server for Hot Service (Oracle ILOM CLI)
- Oracle ILOM Web InterfacePrepare the Server for Hot Service (Oracle ILOM Web Interface)
I
- illustrated parts breakdownIllustrated Parts Breakdown
- immediate power off
- Power Control, Shutdown, and Reset States
- Powering Down the Server
- indicatorsControls and Indicators
- AC power blockAC Power Block Inlet Indicators
- back panel
- About Controls and Indicators
- Switches and Buttons Reference
- Back Panel Components
- blink ratesStatus Indicator Blink Rates
- charge statusTroubleshooting Using a CMOD Fault Remind Test Circuit
- DPCCDual PCIe Card Carrier (DPCC) Indicators
- dual PCIe card carrier (DPCC)DPCC Indicator Panel
- fan modulesFan Module (FM) Indicators
- Fault-Service Required
- front panelFront Indicator Module (FIM) Panel
- FIMFront Indicator Module (FIM) Panel
- front panel
- About Controls and Indicators
- Front Panel Components
- HBASwitches and Buttons Reference
- Locate Button/LED
- Turn On the Locate Button/LED Remotely (Oracle ILOM Web Interface)
- Turn On the Locate Button/LED Remotely (Oracle ILOM CLI)
- Locate Button/LED Indicator On
- Switches and Buttons Reference
- front panelFront Indicator Module (FIM) Panel
- Locate Button/LED indicatorControl the Locate Button/LED Locally
- NAC namesSystem Indicators Network Access Control (NAC) Names
- normal operating stateServer Boot Process and Normal Operating State Indicators
- OvertemperatureFront Indicator Module (FIM) Panel
- Power OKSwitches and Buttons Reference
- front panelFront Indicator Module (FIM) Panel
- power supply (PS)
- Power Supply Overview
- Power Supply (PS) Indicators
- SMODSwitches and Buttons Reference
- SPSwitches and Buttons Reference
- front panelFront Indicator Module (FIM) Panel
- storage driveStorage Drive Indicators
- system module (SMOD)System Module (SMOD) Indicators
- testFront Panel Lamp Test
- troubleshootingTroubleshooting Using Status Indicators
- installing components
- batteryInstall the System Battery
- CMODInstall a CMOD
- CMOD coverInstall the CMOD Cover
- DIMMsInstall a DIMM
- DPCCInstall a DPCC
- fan frameInstall a Fan Frame
- fan modulesInstall a Fan Module
- FIMInstall the FIM
- HBAInstall the HBA Card
- midplane assemblyInstall the Midplane Assembly
- PCIe cardInstall a PCIe Card
- power supply (PS)Install a Power Supply
- processorsInstall a Processor
- SMODInstall an SMOD
- storage driveInstall a Storage Drive
- USB flash drive (internal)Install the Internal USB Drive
- internal USB flash driveServicing Internal USB Flash Drives (FRU)
- internal USB flash drives
- serviceabilityField-Replaceable Units
- IO allocation
- enabling and disabling resourcesConfigure I/O Resource Allocation
- IO BIOS screenBIOS IO Menu Selections
- IPMI typeMonitoring System Components
L
- LEDs
- power supply (PS)Power Supply Overview
- See indicators.Troubleshooting Using Status Indicators
- testFront Panel Lamp Test
- Locate Button/LED indicator
- controllingControl the Locate Button/LED Locally
- CLITurn On the Locate Button/LED Remotely (Oracle ILOM CLI)
- controlling the Locate Button/LED indicatorTurn On the Locate Button/LED Remotely (Oracle ILOM Web Interface)
- managingManaging the Locate Button/LED
- LRDIMMs
- serviceServicing DIMMs (CRU)
M
- Main BIOS screenBIOS Main Menu Selections
- Main powerPower Control, Shutdown, and Reset States
- memory
- descriptionCMOD Memory
- faultMemory Fault
- replacingServicing DIMMs (CRU)
- serviceServicing DIMMs (CRU)
- slot locationsDIMM Physical Layout
- menus, BIOS Setup UtilityAccess BIOS Setup Utility Menus
- midplane assembly
- installingInstall the Midplane Assembly
- removingRemove the Midplane Assembly
- serviceServicing the Midplane Assembly (FRU)
- serviceabilityField-Replaceable Units
- monitoring
- component faultsMonitoring Component Health and Faults Using Oracle ILOM
- componentsMonitoring System Components
- motherboard assembly
- serviceabilityField-Replaceable Units
N
- NAC namesSystem Components (FRUs) Network Access Control (NAC) Names
- Network Time Protocol (NTP)Install the System Battery
- NMI
- reset buttonSwitches and Buttons Reference
- NMI buttonBack Panel Pinhole Switches
O
- on-board test circuitTroubleshooting Using a CMOD Fault Remind Test Circuit
- Oracle Integrated Lights Out Manager (ILOM)
- assign serial port output
- CLIAssign Serial Port Output (Oracle ILOM CLI)
- web interfaceAssign Serial Port Output (Oracle ILOM Web Interface)
- controlling the Locate Button/LED indicatorTurn On the Locate Button/LED Remotely (Oracle ILOM Web Interface)
- fault management shell
- Clear Hardware Fault Messages (Oracle ILOM)
- Managing Server Hardware Faults Using the Oracle ILOM Fault Management
Shell
- key identity properties (KIP) for FRUID auto-update featureFRU Key Identity Properties (KIP) Automated Update
- over-temperature
- faultOver Temperature Condition
- overview
- back panel componentsChassis Back Panel Components
- chassisServer Chassis Overview
- CMODCPU Module (CMOD) Overview
- front panel componentsChassis Front Panel Components
- serverProduct Description
- SMODSystem Module (SMOD) Overview
- storage drivesServer Storage Drives
P
- PCIe cards
- installing componentsInstall a PCIe Card
- overviewPCIe Card and DPCC Overview
- population rulesDPCC Population Rules
- removingRemove a PCIe Card
- serviceServicing PCIe Cards and Carriers (CRU)
- serviceabilityCustomer-Replaceable Units
- slot locationsDPCC and PCIe Card Slot Locations and Numbering
- slot numberingDPCC and PCIe Card Slot Locations and Numbering
- slotsServer PCIe Card Slots
- power
- button
- Power Off the Server for Immediate Shutdown (Power Button)
- Power Off the Server Gracefully (Power Button)
- modes, shutdowns, and resetsPower Control, Shutdown, and Reset States
- removalPowering Down the Server
- subsystemPower Subsystem
- power supply (PS)
- faultPS Fault
- indicatorsPower Supply (PS) Indicators
- installingInstall a Power Supply
- LEDsPower Supply Overview
- locationsPower Supply Locations and Numbering
- overviewPower Supply Overview
- removingRemove a Power Supply
- serviceServicing Power Supplies (CRU)
- serviceabilityCustomer-Replaceable Units
- powering off server
- emergencyPower Off the Server for Immediate Shutdown (Power Button)
- graceful power offPowering Down the Server
- gracefully, using Oracle ILOM CLIPower Off the Server Gracefully (Oracle ILOM CLI)
- gracefully, using Oracle ILOM web interfacePower Off the Server Gracefully (Oracle ILOM Web Interface)
- gracefully, using the Power buttonPower Off the Server Gracefully (Power Button)
- immediate power offPowering Down the Server
- immediately, using Oracle ILOM CLIPower Off the Server for Immediate Shutdown (Oracle ILOM CLI)
- immediately, using Oracle ILOM web interfacePower Off the Server for Immediate Shutdown (Oracle ILOM Web Interface)
- immediately, using the Power buttonPower Off the Server for Immediate Shutdown (Power Button)
- power removalRemove Power
- server OSPower Off the Server Using the Server OS
- powering on server
- using Oracle ILOM CLIPower On the Server
- using Oracle ILOM web interfacePower On the Server
- processor-heatsink module
- socket coverPrepare a CMOD for Replacement
- processors
- faultCPU Fault
- identificationIdentify and Remove a Faulty Processor
- identifying faulty processorIdentify and Remove a Faulty Processor
- installingInstall a Processor
- maximum DIMMs supportedDIMM Population Rules
- overviewCMOD Processor
- physical layoutDIMM Physical Layout
- processor heatsink module (PHM)CMOD Components
- removingIdentify and Remove a Faulty Processor
- replacingServicing Processors (FRU)
- serviceServicing Processors (FRU)
- serviceabilityField-Replaceable Units
- supported
- Oracle X7-8 CPU Packages
- Product Description
R
- RDIMMs
- serviceServicing DIMMs (CRU)
- removing
- antistatic measuresPrepare the Server for Operation
- CMOD coverRemove the CMOD Cover
- power, completely
- Power Control, Shutdown, and Reset States
- Remove Power
- Powering Down the Server
- removing components
- batteryRemove the System Battery
- CMODRemove a CMOD
- DIMMsIdentify and Remove a Faulty DIMM
- DPCCRemove a DPCC
- fan frameRemove a Fan Frame
- fan modulesRemove a Fan Module
- FIMRemove the FIM
- HBARemove the HBA Card
- midplane assemblyRemove the Midplane Assembly
- PCIe cardRemove a PCIe Card
- power supply (PS)Remove a Power Supply
- processorsIdentify and Remove a Faulty Processor
- SMODRemove an SMOD
- storage driveRemove a Storage Drive
- USB flash driveRemove the Internal USB Flash Drive
- replacing components
- DIMMsIdentify and Remove a Faulty DIMM
- energy storage module (ESM)Replace the Energy Storage Module
- ESM extension cableReplace the ESM Extension Cable
- memoryServicing DIMMs (CRU)
- processorsServicing Processors (FRU)
- SAS cableReplace the SAS Cable
- SMODServicing System Module (SMOD) Components (FRU)
- system batteryServicing the System Battery (CRU)
- reset server
- coldPower Control, Shutdown, and Reset States
- warmPower Control, Shutdown, and Reset States
- RTC battery, replacingServicing the System Battery (CRU)
S
- safety symbolsSafety Symbols
- SAS cables
- locationSMOD Components
- replacingReplace the SAS Cable
- serviceServicing the SAS Cable (FRU)
- serviceabilityField-Replaceable Units
- Save and Exit BIOS screenBIOS Save and Exit Menu Selections
- screens, BIOS Setup Utility
- Access BIOS Setup Utility Menus
- BIOS Setup Utility Menus
- serial number, locatingLocating the Chassis Serial Number
- server
- Auto Service RequestAuto Service Requests
- boot processServer Boot Process and Normal Operating State Indicators
- configuring the server for operationConfiguring the System Socket Modes
- contacting supportContacting Support
- descriptionProduct Description
- diagnosticsTroubleshooting and Diagnostics
- faultsDetecting and Managing Server Faults
- powering off immediately, using the Power buttonPower Off the Server for Immediate Shutdown (Power Button)
- prepare the server for servicingPreparing for Service
- returning server to operationReturning the Server to Operation
- serial number, locatingLocating the Chassis Serial Number
- troubleshooting
- Troubleshooting Using Status Indicators
- Troubleshooting Using Diagnostic Tools
- Troubleshooting and Diagnostics
- troubleshooting hardware faultsTroubleshooting Server Hardware Faults
- verifying server socket modeVerify the Current Socket Mode Configuration
- server boot process
- LEDsServer Boot Process and Normal Operating State Indicators
- service
- coldComponent Serviceability Requirements
- CPU module (CMOD)Servicing CPU Module (CMOD) Components (FRU)
- energy storage module (ESM)Servicing the Energy Storage Module and Cables (CRU)
- ESM extension cableServicing the Energy Storage Module and Cables (CRU)
- fan framesServicing Fan Modules (CRU) and Fan Frames (CRU)
- fan modulesServicing Fan Modules (CRU) and Fan Frames (CRU)
- front indicator module (FIM)Servicing the Front Indicator Module (FRU)
- host bus adapter (HBA)Servicing the Host Bus Adapter (HBA) Card (FRU)
- hotComponent Serviceability Requirements
- memory (DIMMs)Servicing DIMMs (CRU)
- midplane assemblyServicing the Midplane Assembly (FRU)
- PCIe cardsServicing PCIe Cards and Carriers (CRU)
- power supply (PS)Servicing Power Supplies (CRU)
- processors (CPUs)Servicing Processors (FRU)
- SAS cablesServicing the SAS Cable (FRU)
- SMODServicing System Module (SMOD) Components (FRU)
- storage drivesServicing Storage Drives (CRU)
- USB flash drive (internal)Servicing Internal USB Flash Drives (FRU)
- warmComponent Serviceability Requirements
- service processor (SP)SMOD Motherboard
- faultService Processor Fault
- reset button
- Back Panel Pinhole Switches
- Switches and Buttons Reference
- service, hot, warm, or cold
- Field-Replaceable Units
- Customer-Replaceable Units
- Component Serviceability Requirements
- serviceability requirements
- Field-Replaceable Units
- Customer-Replaceable Units
- Component Serviceability Requirements
- set commandInstall a Processor
- shortcut key sequences, BIOS Setup UtilityBIOS Key Mappings
- show commandInstall a Processor
- SMOD
- shippingPrepare an SMOD for Replacement
- Standby power
- Power Control, Shutdown, and Reset States
- Power Off the Server for Immediate Shutdown (Power Button)
- static prevention
- antistatic matUsing an Antistatic Mat
- antistatic wrist strapUsing an Antistatic Wrist Strap
- stop commandPower Off the Server Gracefully (Oracle ILOM CLI)
- storage drive
- backplanesSMOD Motherboard
- indicatorsStorage Drive Indicators
- installingInstall a Storage Drive
- overviewServer Storage Drives
- population rulesStorage Drive Population Rules
- referenceStorage Drive Locations and Numbering
- removingRemove a Storage Drive
- serviceServicing Storage Drives (CRU)
- serviceabilityCustomer-Replaceable Units
- slot designationsStorage Drive Slot Locations
- subsystem
- cooling subsystemCooling Subsystem
- I/O subsystemI/O Subsystem
- memory subsystemMemory Subsystem
- networking subsystemNetworking Subsystem
- PCI devices subsystemPCI Devices Subsystem
- power subsystemPower Subsystem
- processor subsystemProcessor Subsystem
- storage subsystemStorage Subsystem
- support, productContacting Support
- switchesSwitches and Buttons Reference
- host reset
- back panelBack Panel Pinhole Switches
- SP reset
- back panelBack Panel Pinhole Switches
- system
- battery, replacingServicing the System Battery (CRU)
- componentsSystem Indicators Network Access Control (NAC) Names
- components and nomenclatureMonitoring System Components
- NAC namesSystem Sensors Network Access Control (NAC) Names
- preparing for cold service
- Prepare the Server for Cold Service (Oracle ILOM Web Interface)
- Prepare the Server for Cold Service (Oracle ILOM CLI)
- preparing for hot service
- Prepare the Server for Hot Service (Oracle ILOM Web Interface)
- Prepare the Server for Hot Service (Oracle ILOM CLI)
- preparing for warm service
- Prepare the Server for Warm Service (Oracle ILOM Web Interface)
- Prepare the Server for Warm Service (Oracle ILOM CLI)
- sensorsSystem Sensors Network Access Control (NAC) Names
- status indicators, frontFront Indicator Module (FIM) Panel
- system module (SMOD)
- componentsSMOD Components
- indicators and switchesSystem Module (SMOD) Indicators
- installingInstall an SMOD
- motherboardSMOD Motherboard
- overviewSystem Module (SMOD) Overview
- population rulesSMOD Population Rules
- removingRemove an SMOD
- replacingServicing System Module (SMOD) Components (FRU)
- serviceServicing System Module (SMOD) Components (FRU)
- storage drivesServer Storage Drives
T
- technical supportContacting Support
- test circuitTroubleshooting Using a CMOD Fault Remind Test Circuit
- thermal interface material (TIM)CMOD Components
- tools and equipment
- required for serviceRequired Tools and Equipment
- troubleshooting
- contacting supportContacting Support
- cooling issuesTroubleshooting System Cooling Issues
- diagnostic toolsDiagnostic Tools
- fault management shell
- Oracle ILOMManaging Server Hardware Faults Using the Oracle ILOM Fault Management
Shell
- hardware faultsTroubleshooting Server Hardware Faults
- indicatorsTroubleshooting Using Status Indicators
- power issuesTroubleshooting Power Issues
- server
- Troubleshooting Using Status Indicators
- Troubleshooting Using Diagnostic Tools
- Troubleshooting and Diagnostics
- Trusted Execution Technology (TXT)
- descriptionTrusted Execution Technology
- enabling and disablingConfigure Trusted Execution Technology
- Trusted Platform Module (TPM)
- enabling and disablingConfigure TPM Support
U
- UEFI driver
- enabling and disablingConfigure UEFI Driver Settings
- UEFI Secure Boot
- descriptionUEFI Secure Boot
- enabling and disablingConfigure UEFI Secure Boot
- upgrading the serverUpgrade the Server From Four to Eight CMODs (FRU)
- USB flash drive (internal)
- installingInstall the Internal USB Drive
- removingRemove the Internal USB Flash Drive
- serviceServicing Internal USB Flash Drives (FRU)
- USB ports, internalSMOD Motherboard
V
- verifying server CMOD configurationVerify the CMOD Configuration
- verifying server socket modeVerify the Current Socket Mode Configuration
W
- warm service, preparing the server
- Oracle ILOM CLIPrepare the Server for Warm Service (Oracle ILOM CLI)
- Oracle ILOM Web InterfacePrepare the Server for Warm Service (Oracle ILOM Web Interface)