Front Panel Components

The following figure shows Oracle Server X7-8 chassis front panel components:

image:An illustration showing the front of the system with component                         callouts
Call Out
Component
Link
1
Front indicator module (FIM). The FIM provides separate controls and system status LED indicators for System A and System B while in 4-socket mode.
  • Chassis/SMOD0 System A controls and indicators:

    Locate Button/LED: white

    Fault-Service Required LED: amber

    System OK LED indicator: green

    On/Standby button, recessed

    SP OK: green

    System Overtemperature Warning LED: amber

    Chassis or SMOD0 System A Fault-Service Required: Amber

    CMOD0-3 Fault-Service Required LEDs 0, 1, 2, 3: amber

  • SMOD1 System B controls and indicators:

    Locate Button/LED: white

    Fault-Service Required LED: amber

    System OK indicator: green

    On/Standby button, recessed

    SP OK: green

    System Overtemperature Warning LED: amber

    Rear Fault-Service Required LED: amber

    CMOD4-7 Fault-Service Required LEDs 4, 5, 6, 7: amber

2
Four power supplies (PS)
Power supplies 0 (bottom) through 3 (top) labeled PS0, PS1, PS2, PS3
PS2 and PS3 power System A. PS0 and PS1 power System B.
3
Eight fan modules (FM)
Fan modules FM0 through FM7: Top row: 1, 3, 5, 7 Bottom row: 0, 2, 4, 6
SMOD0 System A: FM 0, 1, 2, 3; SMOD1 System B: FM 4, 5, 6, 7
4
Two fan frames
SMOD0 System A: FM 0, 1, 2, 3; SMOD1 System B: FM 4, 5, 6, 7
5
Eight internal CPU Modules (CMODs). CMOD bays are accessible behind the fan frames.
System A: CMODs 0-3; System B: CMODs 4-7.
4-socket mode: CMODs 0-3. 8-socket mode: CMODs 0-7

For component serviceability, locations, and designations, see Replaceable Components.