Front Panel Components
The following figure shows Oracle Server X7-8 chassis front panel components:
|
|
|
1
|
Front indicator module (FIM). The FIM provides separate
controls and system status LED indicators for System A and
System B while in 4-socket mode.
-
Chassis/SMOD0 System A controls and indicators:
Locate Button/LED: white
Fault-Service Required LED: amber
System OK LED indicator: green
On/Standby button, recessed
SP OK: green
System Overtemperature Warning LED: amber
Chassis or SMOD0 System A Fault-Service Required:
Amber
CMOD0-3 Fault-Service Required LEDs 0, 1, 2, 3:
amber
-
SMOD1 System B controls and indicators:
Locate Button/LED: white
Fault-Service Required LED: amber
System OK indicator: green
On/Standby button, recessed
SP OK: green
System Overtemperature Warning LED: amber
Rear Fault-Service Required LED: amber
CMOD4-7 Fault-Service Required LEDs 4, 5, 6, 7:
amber
|
|
2
|
Four power supplies (PS)
Power supplies 0 (bottom) through 3 (top) labeled PS0, PS1,
PS2, PS3
PS2 and PS3 power System A. PS0 and PS1 power System B.
|
|
3
|
Eight fan modules (FM)
Fan modules FM0 through FM7: Top row: 1, 3, 5, 7 Bottom row:
0, 2, 4, 6
SMOD0 System A: FM 0, 1, 2, 3; SMOD1 System B: FM 4, 5, 6,
7
|
|
4
|
Two fan frames
SMOD0 System A: FM 0, 1, 2, 3; SMOD1 System B: FM 4, 5, 6,
7
|
|
5
|
Eight internal CPU Modules (CMODs). CMOD bays are accessible
behind the fan frames.
System A: CMODs 0-3; System B: CMODs 4-7.
4-socket mode: CMODs 0-3. 8-socket mode: CMODs 0-7
|
|
|
For component serviceability, locations, and designations, see Replaceable Components.