Go to main content

Oracle® Server X7-8 Service Manual

Exit Print View

Updated: April 2019
 
 

SMOD Motherboard

Each SMOD motherboard contains:

  • Two Storage Drive Backplanes (for externally accessible server storage drives)

    Externally accessible server storage drives on the SMOD connect to two storage drive backplanes mounted on the SMOD motherboard. One SAS cable connects each backplane to the HBA card that is installed in a riser slot on the underside of the SMOD. Storage drive backplanes are not removable or replaceable.

  • Service processor (SP)

    The system Emulex Pilot 4 service processor (SP) is located on the SMOD motherboard and is accessible locally and remotely through management ports on the front of the SMOD. The SP contains Oracle ILOM, an embedded server management tool. The SP is not removable.

  • System real time clock battery, 3V lithium coin cell battery

  • Energy storage module (ESM) for the server storage HBA

    The ESM provides backup power for the Oracle Storage 12Gb SAS PCIe RAID HBA, Internal 16-Port card. The ESM is located in a holder in the top center of the SMOD. A cable connects the HBA to to the ESM.

  • PCIe riser for the server storage HBA, located on the bottom of the SMOD

    The server requires one internal HBA (Oracle Storage 12Gb SAS PCIe RAID HBA, Internal 16-Port) for the externally accessible SAS (or SATA) SMOD server storage drives. The HBA is installed in a riser slot on the underside of the SMOD motherboard and is connected to the backplanes by one mini-SAS4I connector cable.

  • One internal USB 3.0 port, located on the bottom of the SMOD.

    Each SMOD has one unused internal USB 3.0 port that is designated as P0. The port is located on the underside of the SMOD motherboard next to the PCIe card riser slot.

For component serviceability, locations, and designations, see Replaceable Components.

For replacement procedures, see Servicing System Module (SMOD) Components (FRU).