Configure RAID in UEFI BIOS Boot Mode

  1. Power on or reset the server.

    For example, to reset the server:

    • From the local server, press the Power button (approximately 1 second) on the front panel of the server to power off the server, then press the Power button again to power on the server.

    • From the Oracle ILOM web interface, select Host Management > Power Control, then select Reset from the Select Action list box.

    • From the Oracle ILOM CLI, type: reset /System

    The BIOS screen appears.

  2. When prompted in the BIOS screen, press F2 to access the BIOS Setup Utility.

    After a few moments, the BIOS Setup Utility appears.

  3. Use the right arrow key to navigate to the Advanced menu.

    The Advanced menu appears.

  4. Use the up and down arrow keys to navigate to the LSI SAS2 MPT Controller menu option, and press Enter.
    image:Graphic showing the BIOS Advanced menu screen.
  5. Use the BIOS configuration utility to configure RAID on the server.

    For instructions on how to use the BIOS configuration utilities to configure RAID in UEFI BIOS Boot Mode, refer to instructions for creating a bootable drive on x86/64 systems in the Sun Storage 6 Gb SAS PCIe HBA, Internal Installation Guide For HBA Models SGX-SAS6-INT-Z and SG-SAS6-INT-Z at: http://docs.oracle.com/cd/E19337-01/index.html.

Next Steps