Netra Server X5-2 Service Manual

Exit Print View

Updated: October 2016
 
 

Verify a DIMM

After you install a DIMM, you can verify its functionality.

  1. Access Oracle ILOM.

    See Access the SP (Oracle ILOM).

  2. Reset the DIMM.
    -> set /SYS/MB/Px/Dy clear_fault_action=true
    Are you sure you want to clear /SYS/MB/P0/D7 (y/n)? y
    Set 'clear_fault_action' to 'true'
    
    ->
  3. Consider your next step.
    • If you installed a new DIMM as part of a replacement operation, verify that the DIMM is no longer considered faulty, then return to this procedure. See Locate a Faulty DIMM.

    • If you installed a new DIMM to increase functionality, go to Step 4.

  4. Verify that the DIMM is recognized.
    -> show /System/Memory/DIMMs
     /System/Memory/DIMMs
     	Targets:
     		DIMM_x
     		DIMM_y
    ...
    ->

    where x, y, or so on, is the slot number where the DIMM is installed.

  5. Verify that the DIMM is identified.
    -> show /System/Memory/DIMMs/DIMM_x 

    where x is the slot number where the DIMM is installed.

Related Information