System Management
Power Supply Policies Configurable From CMM
System administrators can optionally set system management
policies from the CMM to manage chassis power supply demand, power
supply fan speeds, storage blade SAS-2 capability, and chassis power
management.
For property descriptions of the system management policies
that are configurable from the CMM, see the following table:
Table 87 Configurable CMM Power Supply Policies
|
|
|
|
Light Load Efficiency Mode
(LIGHT_LOAD_EFFICIENCY_MODE=) |
Disabled |
Disabled |Enabled
Enable this policy to: 1) monitor the chassis system power usage; and 2) automatically shut
down the power supply unit sides to achieve higher
efficiency.
CLI Syntax for Light Load Efficiency
Mode:
set /CMM/policy LIGHT_LOAD_EFFICIENCY_MODE=enabled|disabled |
Monitor Power Supply 0 Side
0 for power
(MONITOR_PS0_SIDE0=) |
Enabled |
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 0
Side 0 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply
0 Side 0:
set /CMM/policy MONITOR_PS0_SIDE0=enabled|disabled |
Monitor Power Supply 0 Side
1 for power
(MONITOR_PS0_SIDE1=) |
Enabled |
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 0
Side 1 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply
0 Side 1:
set /CMM/policy MONITOR_PS0_SIDE1=enabled|disabled |
Monitor Power Supply 1 Side
0 for power
(MONITOR_PS1_SIDE0=) |
Enabled |
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 1
Side 0 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply
1 Side 0:
set /CMM/policy MONITOR_PS1_SIDE0=enabled|disabled |
Monitor Power Supply 1 Side
1 for power
(MONITOR_PS1_SIDE1=) |
Enabled |
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 1
Side 1 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply
1 Side 1:
set /CMM/policy MONITOR_PS1_SIDE1=enabled|disabled |
Cooling Door Installed
(COOLING_DOOR_INSTALLED=) |
Disabled |
Disabled |Enabled
Enable this policy to support a cooling door installed on
a Sun Blade 6048 chassis.
CLI Syntax for Cooling Door Installed:
set /CMM/policy COOLING_DOOR_INSTALLED=enabled|disabled |
Force Power Supply Fans
to High Speed
(PS_FANS_HIGH=) |
Disabled |
Disabled |Enabled
Enable this policy to force the power supply fans to 100%
capacity.
CLI Syntax for Force Power Supply
Fans to High Speed:
set /CMM/policy PS_FANS_HIGH=enabled|disabled |
Force Power Supply Fans
to Low Speed
(PS_FANS_LOW=) |
Disabled |
Disabled |Enabled
Enable this policy to force the power supply fans to 80% capacity.
CLI Syntax for Force Power Supply
Fans to Low Speed:
set /CMM/policy PS_FANS_LOW=enabled|disabled |
Force Server Blade to be
SAS2 Capable at 3Gbps.
(FORCE_SAS2_3GBPS=) |
Disabled |
Disabled |Enabled
Enable this policy to force the NEM(s) to run the SAS link
at a slower rate, for those rare cases when this action is necessary.
CLI Syntax for Force Server Blade
to be SAS2 Capable at 3Gbps:
set /CH/BLn/SP/policy FORCE_SAS2_3GBPS=enabled|disabled |
Manage chassis power.
Caution - Disabling may lead to
chassis shutdown. |
(POWER_MANAGEMENT=) |
Enabled |
Disabled |Enabled
Enable this policy to determine whether there is enough power
in the chassis to power on a new server module installed in the
chassis.
CLI Syntax for Manage Chassis Power:
Caution - Disabling may lead to
chassis shutdown. |
set /CMM/policy POWER_MANAGEMENT=enabled|disabled |
|