Go to main content
oracle home
Sun Netra X4270 Server
Exit Print View
Search Term
Search Scope:
This Document
Entire Library
» ...
Documentation Home
»
Sun Netra X4270 Server Documentation Library
»
Sun Netra X4270 Server
Updated: September 2015
Sun Netra X4270 Server
Document Information
Using This Documentation
Product Documentation Library
Related Documentation
Feedback
Understanding the Server
Locating Controls and Connectors
Front Panel Controls On Two-Drive System
Front Panel Components on Two-Drive Systems With Bezel Removed
Front Panel Components on Four-Drive Systems With Bezel Removed
Rear Panel Cable Connections
Locating Server and Component LEDs
System Status LEDs
User Alarm LEDs
Drive LEDs
Rear Panel LED Locations
Power Supply LEDs
Ethernet Port LEDs
System Components
Field-Replaceable Units
Inspecting the Server
Diagnostic Tools
Service Troubleshooting Task List
Gather Service Information
Inspecting the System
Troubleshoot Power Problems
Inspect the Server Externally
Inspect Internal Server Components
Using the BIOS Setup Utility
Understanding BIOS Booting and Setup
Default BIOS POST Events
BIOS POST F1 and F2 Errors
BIOS POST Memory Testing Process
Ethernet Port Device and Driver Naming
Ethernet Port Booting Priority
BIOS Setup Utility Menus
BIOS Setup Utility Hot Keys
Access the BIOS Setup Utility Menus
View Event Logs
Set Watchdog Timers
Configure TPM Support
Configure SP LAN Settings
Option ROM Allocation
Enable or Disable Option ROM Settings
BIOS Firmware Updates
Understanding BIOS Setup Screens
BIOS Main Menu Screens
BIOS Advanced Menu Screens
BIOS PCI Menu Screen
BIOS Boot Menu Screens
BIOS Security Menu Screen
BIOS Chipset Menu Screens
BIOS Exit Menu Screen
Exit the BIOS Setup Utility
Preparing for Service
Safety Precautions
Safety Symbols
Electrostatic Discharge Safety
Required Tools
Preparing the Server for Component Replacement
Powering Down the Server
Power Down Server Gracefully
Power Down Server Gracefully Using the Power Button
Power Down Server For an Emergency
Disconnect Cables From the Server
Remove the Server From the Rack
Take Antistatic Measures
Remove the Top Cover
Replacing Storage Components
Opening and Closing the Front Bezel
Open Front Bezel
Close Front Bezel
Replacing a Drive
Drives Hot-Plug Conditions
Remove a Drive
Install a Drive
Replacing the Optical Media Drive
Remove the Optical Media Drive
Install the Optical Media Drive
Replacing the Media Bay Assembly
Remove the Media Bay Assembly
Install the Media Bay Assembly
Replacing Motherboard Assembly Components
Replacing the PCI Mezzanine
Remove the PCI Mezzanine
Install the PCI Mezzanine
Replacing PCIe2 Risers
PCIe2 Riser Location and Differences
Remove a PCIe2 Riser
Install a PCIe2 Riser
Replacing PCIe2 Cards
PCIe2 Slot Characteristics
PCI Mezzanine Auxiliary Power Connector
Replacing PCIe2 Cards in Slots 4 and 5
Remove PCIe2 Cards From Slots 4 and 5
Install PCIe2 Cards Into Slots 4 and 5
Replacing the SAS Controller HBA
Remove the SAS Controller HBA
Install the SAS Controller HBA
Replacing Lower PCIe2 Cards
Remove the Lower PCIe2 Cards
Install the Lower PCIe2 Cards
Replacing the Air Duct
Remove the Air Duct
Install the Air Duct
Replacing DIMMs
DIMM and CPU Physical Layout
DIMM Population Rules
DIMM Considerations and Limitations
DIMM Rank Classification Labels
Error Correction and Parity
Identify and Remove Faulty DIMMs
Install DIMMs
Replacing Flash Modules
Remove a Flash Module
Install a Flash Module
Replacing the Flash Module Cable
Remove the Flash Module Cable
Install the Flash Module Cable
Replacing the ESM Riser and ESM
ESM Fault LEDs
Troubleshoot ESM Faults
Remove ESM Riser
Install ESM Riser
Replace the ESM
Replacing the Battery
Remove the Battery
Install the Battery
Replacing CPUs
Remove a CPU
Install a CPU
Install a Second CPU
Replacing the Motherboard Assembly
Remove the Motherboard Assembly
Install the Motherboard Assembly
Reset the BIOS Password and Clear the CMOS NVRAM
Replacing Chassis Components
Replacing the Air Filter
Remove the Air Filter
Install the Air Filter
Replacing Power Supplies
Remove a Power Supply
Install a Power Supply
Replacing Fan Tray 0
Remove Fan Tray 0
Install Fan Tray 0
Replacing Fan Tray 2
Remove Fan Tray 2
Install Fan Tray 2
Replacing Fan Tray 1
Remove Fan Tray 1
Install Fan Tray 1
Replacing the LED Board
Remove the LED Board
Install the LED Board
Replacing the Power Distribution Board
Remove the Power Distribution Board
Install the Power Distribution Board
Returning Server to Operation
Install the Top Cover
Remove Antistatic Measures
Reinstall the Server Chassis in the Rack
Reconnect Power and Data Cables
Power On the Server
Identifying the Server Ports
Gigabit Ethernet Ports
Network Management Port
Serial Management Port
Video Connector
Alarm Port
USB Ports
External SAS Connector
PCI Mezzanine Auxiliary Power Connector
Glossary
Index
Index A
Index B
Index C
Index D
Index E
Index F
Index G
Index H
Index I
Index L
Index M
Index N
Index O
Index P
Index R
Index S
Index T
Index U
Index V
Index W
Language:
English
Sun Netra X4270 Server
Service Manual
September 2015
Troubleshoot and service the server.
Document Information
Using This Documentation
Product Documentation Library
Related Documentation
Feedback
Understanding the Server
Locating Controls and Connectors
Front Panel Controls On Two-Drive System
Front Panel Components on Two-Drive Systems With Bezel Removed
Front Panel Components on Four-Drive Systems With Bezel Removed
Rear Panel Cable Connections
Locating Server and Component LEDs
System Status LEDs
User Alarm LEDs
Drive LEDs
Rear Panel LED Locations
Power Supply LEDs
Ethernet Port LEDs
System Components
Field-Replaceable Units
Inspecting the Server
Diagnostic Tools
Service Troubleshooting Task List
Gather Service Information
Inspecting the System
Troubleshoot Power Problems
Inspect the Server Externally
Inspect Internal Server Components
Using the BIOS Setup Utility
Understanding BIOS Booting and Setup
Default BIOS POST Events
BIOS POST F1 and F2 Errors
BIOS POST Memory Testing Process
Ethernet Port Device and Driver Naming
Ethernet Port Booting Priority
BIOS Setup Utility Menus
BIOS Setup Utility Hot Keys
Access the BIOS Setup Utility Menus
View Event Logs
Set Watchdog Timers
Configure TPM Support
Configure SP LAN Settings
Option ROM Allocation
Enable or Disable Option ROM Settings
BIOS Firmware Updates
Understanding BIOS Setup Screens
BIOS Main Menu Screens
BIOS Advanced Menu Screens
BIOS PCI Menu Screen
BIOS Boot Menu Screens
BIOS Security Menu Screen
BIOS Chipset Menu Screens
BIOS Exit Menu Screen
Exit the BIOS Setup Utility
Preparing for Service
Safety Precautions
Safety Symbols
Electrostatic Discharge Safety
Required Tools
Preparing the Server for Component Replacement
Powering Down the Server
Power Down Server Gracefully
Power Down Server Gracefully Using the Power Button
Power Down Server For an Emergency
Disconnect Cables From the Server
Remove the Server From the Rack
Take Antistatic Measures
Remove the Top Cover
Replacing Storage Components
Opening and Closing the Front Bezel
Open Front Bezel
Close Front Bezel
Replacing a Drive
Drives Hot-Plug Conditions
Remove a Drive
Install a Drive
Replacing the Optical Media Drive
Remove the Optical Media Drive
Install the Optical Media Drive
Replacing the Media Bay Assembly
Remove the Media Bay Assembly
Install the Media Bay Assembly
Replacing Motherboard Assembly Components
Replacing the PCI Mezzanine
Remove the PCI Mezzanine
Install the PCI Mezzanine
Replacing PCIe2 Risers
PCIe2 Riser Location and Differences
Remove a PCIe2 Riser
Install a PCIe2 Riser
Replacing PCIe2 Cards
PCIe2 Slot Characteristics
PCI Mezzanine Auxiliary Power Connector
Replacing PCIe2 Cards in Slots 4 and 5
Remove PCIe2 Cards From Slots 4 and 5
Install PCIe2 Cards Into Slots 4 and 5
Replacing the SAS Controller HBA
Remove the SAS Controller HBA
Install the SAS Controller HBA
Replacing Lower PCIe2 Cards
Remove the Lower PCIe2 Cards
Install the Lower PCIe2 Cards
Replacing the Air Duct
Remove the Air Duct
Install the Air Duct
Replacing DIMMs
DIMM and CPU Physical Layout
DIMM Population Rules
DIMM Considerations and Limitations
DIMM Rank Classification Labels
Error Correction and Parity
Identify and Remove Faulty DIMMs
Install DIMMs
Replacing Flash Modules
Remove a Flash Module
Install a Flash Module
Replacing the Flash Module Cable
Remove the Flash Module Cable
Install the Flash Module Cable
Replacing the ESM Riser and ESM
ESM Fault LEDs
Troubleshoot ESM Faults
Remove ESM Riser
Install ESM Riser
Replace the ESM
Replacing the Battery
Remove the Battery
Install the Battery
Replacing CPUs
Remove a CPU
Install a CPU
Install a Second CPU
Replacing the Motherboard Assembly
Remove the Motherboard Assembly
Install the Motherboard Assembly
Reset the BIOS Password and Clear the CMOS NVRAM
Replacing Chassis Components
Replacing the Air Filter
Remove the Air Filter
Install the Air Filter
Replacing Power Supplies
Remove a Power Supply
Install a Power Supply
Replacing Fan Tray 0
Remove Fan Tray 0
Install Fan Tray 0
Replacing Fan Tray 2
Remove Fan Tray 2
Install Fan Tray 2
Replacing Fan Tray 1
Remove Fan Tray 1
Install Fan Tray 1
Replacing the LED Board
Remove the LED Board
Install the LED Board
Replacing the Power Distribution Board
Remove the Power Distribution Board
Install the Power Distribution Board
Returning Server to Operation
Install the Top Cover
Remove Antistatic Measures
Reinstall the Server Chassis in the Rack
Reconnect Power and Data Cables
Power On the Server
Identifying the Server Ports
Gigabit Ethernet Ports
Network Management Port
Serial Management Port
Video Connector
Alarm Port
USB Ports
External SAS Connector
PCI Mezzanine Auxiliary Power Connector
Glossary
Index
A
B
C
D
E
F
G
H
I
L
M
N
O
P
R
S
T
U
V
W