Rear Panel
Cable Connections
|
|
|
1 |
|
SAS SFF-8088 connector |
2 |
|
Telco alarm port |
3 |
PCIe2 slot 0 |
X8 PCIe2 low-profile |
4 |
PCIe2 slot 4 |
X8 PCIe2 full-height, full-width |
5 |
PCIe2 slot 1 |
X8 PCIe2 low-profile |
6 |
PCIe2 slot 5 |
X8 PCIe2 full-height, full-width |
7 |
PCIe2 slot 2 |
X8 PCIe2 low-profile |
8 |
|
Labeled PS0 |
9 |
Power Supply 1 |
Labeled PS1 |
10 |
|
SP serial management port |
11 |
|
SP network management port |
12 |
|
Left to right – NET0, NET1,
NET2, NET3 |
13 |
|
System ships with a grounding lug |
14 |
|
Left to right – USB0, USB1 |
15 |
|
VGA port |
|
Note - To comply with NEBS lightning requirements, all I/O
connections (except the Ethernet and power connections) must be
made using shielded cables, and both ends of the shield must be
grounded.
Note - All of the PCIe slots comply with the PCI Express 2.0
specification and can accommodate 25 W PCIe2 cards.