Replacing Power Supplies

The server???s redundant power supplies support concurrent maintenance, which enables you to remove and replace a power supply without shutting the server down, provided that the other power supply is online and working.

The following LEDs are lit when a power supply fault is detected:

  • Front and rear Service Required LEDs

  • Amber Fault LED on the faulty power supply

If a power supply fails and you do not have a replacement available, leave the failed power supply installed to ensure proper air flow in the server.


Caution

Caution  - Safety agency requirements prohibit changing a system from AC input to DC input or from DC input to AC input after the product has been removed from the agency approved manufacturing site.