Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

Display Module Type (Oracle ILOM CLI)

The virtualization switch supports modules of different connection types. The table shows the different I/O module types and their string as displayed by the virtualization switch.

Module
String
Oracle F2 Dual Port 16Gb Fibre Channel
FIBRE CHANNEL, IO MODULE
Oracle F2 10GBASE-T
10GBASE-T,IO MODULE
Oracle F2 10G/40G Ethernet Module
40GE/4x10GE,IO MODULE
Oracle InfiniBand Long Range
IB LR,IO MODULE
  1. Display the installed modules.
    -> show /SYS/MODULES/
    
     /SYS/MODULES
        Targets:
            MODULE0
            MODULE1
            MODULE3
            MODULE5
            MODULE6
            MODULE10
    

    I/O modules in the virtualization switch are numbered 0 to 11 with Module 0 occupying the first (left most) physical slot.

  2. Display the module type.
     show /SYS/MODULES/MODULEX fru_description
      

    where X is a number between 0 or 11 that corresponds to the module slot for which you want to display information.

    For example, to display the module type for module 3, type:

    -> show /SYS/MODULES/MODULE3 fru_description
    
      /SYS/MODULES/MODULE3
        Properties:
            fru_description = PCBA,10GBASE-T,IO MODULE
    
    

Related Information