/SYS Main Board Chassis Targets and Properties
Use the show command on the /SYS/MB targets to
display information about and status for the main board. Use the
set command to configure the
clear_fault_action property to manually clear a main
board fault.
Note -
Properties indicated as Not Supported or
N/A are not listed.
|
|
|
/SYS/MB
|
-
type = Motherboard
-
ipmi_name = MB
-
fru_description = PCBA, W/MECHANICALS,
NM3, LEAF
-
fru_manufacturer = Oracle
Corporation
-
fru_part_number =
7092208
-
fru_rev_level = 06
-
fru_serial_number =
489090M+1507RP0005
-
fru_macaddress =
00:10:e0:56:83:85
-
fault_state = OK
-
clear_fault_action =
(none)
|
Main board management.
|
/SYS/MB/T_AMB
|
-
type = Temperature
-
ipmi_name = MB/T_AMB
-
class = Threshold
Sensor
-
value = 32.000 degree
C
-
upper_critical_threshold = 40.000 degree
C
-
lower_critical_threshold = 0.000 degree
C
-
lower_nonrecov_threshold = -10.000 degree
C
-
alarm_status = cleared
|
Main board ambient temperature information.
|
/SYS/MB/T_HCA
|
-
type = Temperature
-
ipmi_name = MB/T_HCA
-
class = Threshold
Sensor
-
value = 74.000 degree
C
-
upper_nonrecov_threshold = 110.000 degree
C
-
upper_critical_threshold = 100.000 degree
C
-
upper_noncritical_threshold = 90.000
degree C
-
lower_critical_threshold = 0.000 degree
C
-
alarm_status = cleared
|
IB HCA ambient temperature information.
|
/SYS/MB/T_IBSWITCH
|
-
type = Temperature
-
ipmi_name =
MB/T_IBSWITCH
-
class = Threshold
Sensor
-
value = 81.000 degree
C
-
upper_nonrecov_threshold = 110.000 degree
C
-
upper_critical_threshold = 100.000 degree
C
-
upper_noncritical_threshold = 90.000
degree C
-
lower_noncritical_threshold =
N/A
-
lower_critical_threshold = 0.000 degree
C
-
alarm_status = cleared
|
IB switch ambient temperature information.
|
/SYS/MB/T_OUT
|
-
type = Temperature
-
ipmi_name = MB/T_OUT
-
class = Threshold
Sensor
-
value = 36.000 degree
C
-
upper_nonrecov_threshold = 75.000 degree
C
-
upper_critical_threshold = 65.000 degree
C
-
upper_noncritical_threshold = 50.000
degree C
-
lower_critical_threshold = 0.000 degree
C
-
lower_nonrecov_threshold =
-10.000
-
alarm_status = cleared
|
Main board outflow temperature information.
|
/SYS/MB/V_BAT
|
|
Main board battery voltage information.
|
|