Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

/SYS Oracle F2 I/O Module Targets and Properties

The Oracle Fabric Interconnect F2-12 supports numerous types of Oracle F2 I/O modules to customize the switch for your deployment. The Oracle F2 I/O modules are not supported in the leaf switch.

Use the show command on the /SYS/MODULES/MODULEx targets to display information about and status for the Oracle F2 I/O modules installed in your virtualization switch.


Note -  Properties indicated as Not Supported or N/A are not listed in the table. Also, different types of module exist. One module type is used as an example, so some of the properties listed will be different depending on the type of module that Oracle ILOM is querying.
Oracle ILOM Target
Properties
Description
/SYS/MODULES/MODULEx
  • type = Network Module

  • ipmi_name = /MODULEx

  • fru_description = PCBA,NM3 Module

  • fru_manufacturer = Oracle Corporation

  • fru_part_number = 7097301

  • fru_rev_level = 03

  • fru_serial_number = 489089M+1549R0003A

  • fru_mac_address = 00:10:e0:97:f3:68

  • fault_state = OK

  • clear_fault_action = (none)

  • power_state = on

Module x information.
/SYS/MODULES/MODULEx/0V85_OK/
  • type = Voltage

  • ipmi_name = MODULE/0V85_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 0v85 voltage information.
/SYS/MODULES/MODULEx/1V0_OK/
  • type = Voltage

  • ipmi_name = MODULE/1V0_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 1V0 voltage information.
/SYS/MODULES/MODULEx/1V2_OK/
  • type = Voltage

  • ipmi_name = MODULE/1V2_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 1V2 voltage information.
/SYS/MODULES/MODULEx/1V8_OK/
  • type = Voltage

  • ipmi_name = MODULE/1V8_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 1V8 voltage information.
/SYS/MODULES/MODULEx/2V5_OK/
  • type = Voltage

  • ipmi_name = MODULE/1V2_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 2V5 voltage information.
.
/SYS/MODULES/MODULEx/3V3_OK/
  • type = Voltage

  • ipmi_name = MODULE/3V3_OK

  • class = Discrete Sensor

  • value = State Asserted

  • alarm_status = cleared

Module x 3V3 voltage information.
/SYS/MODULES/MODULEx/BOOTED
  • type = Boot

  • class = Discrete Sensor

  • value = State Deasserted

  • alarm_status = cleared

Module x boot up information.
/SYS/MODULES/MODULEx/FAULT
  • type = Module

  • ipmi_name = MODULEX/FAULT

  • class = Discrete Sensor

  • value = State Deasserted

  • alarm_status = cleared

Module x fault information.
/SYS/MODULES/MODULEx/T_CRITICAL
  • type = Module

  • class = Discrete Sensor

  • value = State Deasserted

  • alarm_status = cleared

Module x critical temperature information.
/SYS/MODULES/MODULEx/T_MOD
  • type = Temperature

  • class = Threshold Sensor

  • value = 0.000 degree C

  • upper_nonrecov_threshold = 105.000 degree C

  • upper_critical_threshold = 100.000 degree C

  • upper_noncritical_threshold = 95.000 degree C

  • lower_critical_threshold = -1.000 degree C

  • alarm_status = cleared

Module x temperature threshold information.

Related Information