Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

Display Power Supply Details (Oracle ILOM CLI)

The switch has redundant, load-sharing power supplies numbered either 0 or 1. You can display details, including the PS's FRU number, by displaying details for each PS.

  1. Discover the presence or absence of a specific PS.
    -> show -d properties /SYS/PSslot
    

    where slot is either 0 or 1, corresponding to the PS for which you want to display information.

  2. Display the details for a specific PS.

    For example, to display the details for PS 0.

    -> show -d properties /SYS/PS0
     /SYS/PS0
     	Properties:
     		type = Power Supply
     		ipmi_name = PS0
     		fru_manufacturer = Delta Electronics
     		fru_part_number = 7065505-01
     		fru_serial_number = C94928
     		fault_state = OK
     		clear_fault_action = (none)
    ->
    

Related Information